• Skip to main content
  • Skip to footer
GET IN TOUCH: Call: 617-923-2000 • Email: info@staticworx.com • Contact Us/Request a Sample • Govt Capability Statement View Staticworx's profile on LinkedInView staticworx’s profile on Twitter View staticworx’s profile on Instagram View staticworx’s profile on Pinterest Visit Staticworx's YouTube channel Subscribe to the Staticworx feed

StaticWorx Learning Center

Your trusted source for ESD flooring advice. All your static-control flooring questions answered.

MENUMENU
  • ESD Flooring Choices
    • Government Capability Statement
    • Hospital, Healthcare and Lab ESD Flooring
      • StaticWorx/Dr. Schutz Floor Remake
      • Capability Statement
    • AmeriWorx Vinyl Tile
      • AmeriWorx ESD Solid Vinyl Tile
        • AmeriWorx Classics
        • AmeriWorx ROX
        • Environmental Information
        • Installation Instructions
        • Maintenance Guidelines
        • Post-Installation Maintenance Guidelines
        • Test Reports
      • 10 Reasons to Install Ameriworx SVT in Your Facility
      • Staticworx vs Armstrong ESD Vinyl Tile
      • Compare Imperfect Offshore Tile to AmeriWorx ESD Vinyl Tile
      • Meet Your Buy American Requirements
      • Precision Milled Conductive Flooring
      • VOCs? Heavy metals? What are you breathing from your ESD flooring?
      • Why Vinyl?
    • ShadowFX Carpet Tile
      • ShadowFX SD Carpet Tile
        • Patterns and Cubic Collections
        • Solids Collection
        • Parks Series
        • Peaks Collection
        • Treez Collection
        • Fields and Stone
        • Chenille Warp
        • Furrows II
        • Vermont Slate
          • 5 Reasons to Use Vermont Slate ESD Carpet Tile in 24/7 Critical Environments
        • Vermont Planx™
      • ShadowFX and TacTiles
        • Staticworx Grounding System for Floating Floors
      • 7 Ways ShadowFX ESD Carpet Tile Differs from Commercial Tile
      • ShadowFX Carpet Tile for Access Flooring Applications
      • ShadowFX and ESD Standards
      • Why is ShadowFX Carpet Static Dissipative and Not Conductive?​
      • Premium Helix Monofilament Fibers
      • Fiber Shape and Modification Ratio
    • ESD Urethane & Epoxy Coatings
      • GroundWorx™ Ultra: High-performing ESD Floor
        • CSI Specification
      • GroundWorx™ Basics: Value-engineered ESD Epoxy
      • Body Voltage and ESD Epoxy Coatings
      • Case Study: Generation 3 Epoxy
      • How to Ground ESD Epoxy and Urethane Coatings
    • Message Tiles
    • Rubber Flooring
      • Architectural SD Rubber
      • Eclipse EC Rubber
        • Eclipse Glue-Free (GF) Rubber
      • StatLock Interlocking SD Rubber
      • Voltage Protection Matting
        • Aisle-Safe Runners & Mats
        • GroundCom Matting
        • Switchboard Matting
        • Switchboard Matting: Military-Grade
      • Don’t Choose Your ESD Floor Until You Understand The Role of Footwear
      • Maintaining Rubber Tile and Sheet Flooring
      • Installing Rubber & Vinyl Products
        • Seam Welding for Cleanrooms
    • GroundLock Extreme Interlocking ESD Tiles
    • Access Floors
  • Installation/Maintenance
    • Adhesive-free Underlayments
    • Conductive Adhesives
      • GroundTack Conductive Adhesive
      • StatBond Wet-Set One-Part Acrylic Adhesive
      • StatBond Epoxy Two-Part Wet-Set Adhesive
      • StatBond™ Pressure-Sensitive (PS) Conductive Adhesive
    • Protecting ESD Floors from Moisture
    • TacTiles
    • Static-control Maintenance Supplies
    • Dr. Schutz Remake
  • Blog & Media
    • Blog
    • Statics Bursts Podcast
    • Static Shorts with Dave Long
    • Video Library
  • +Info
    • Architects' Hub
    • Contractors' Hub
    • Owners and Property Managers' Hub
    • ESD Flooring: The Basics
    • What Is ESD Flooring, How Does It Work, And How Do I Choose One?
    • Selecting and Specifying an ESD Floor
      • A Guide to ESD Flooring Selection
    • Installing and Maintaining ESD Floors
    • Technical Information
  • Resources
    • Article Hub
    • FAQs
    • Glossary
    • Video library
    • Archive
    • Standards and Test Methods
  • Lunch & Learn
  • Our Story
    • Contact StaticWorx
    • Government Capability Statement
    • Our History
    • The StaticWorx Green Story
    • Why Choose StaticWorx?
    • Subscribe to Our Newsletter

Case Study: Generation 3 Epoxy

August 21, 2020 by Staticworx

Generation 3 Epoxy

ESD Floor Zaps Static Charge at Electronics Factory

Coatings Pro Magazine by Ben DuBose, March 4, 2019

Generation 3 Epoxy

ESD Floor Zaps Static Charge at Electronics Factory

Coatings Pro Magazine by Ben DuBose, March 4, 2019

For an electronic components manufacturer, electricity is at the heart of business. But static electricity? That’s a very different story.

Ongoing installation of Generation 3 Epoxy flooring at an electronics manufacturing and testing facility That was the conundrum for Extreme Engineering Solutions  (X-ES), which manufactures and tests hardware for the embedded computing market at its headquarters just outside Madison, Wisconsin. Strong sales prompted plans for a new production facility in early 2018, but the nature of the products meant many standard floors would not work. Since static electricity results from friction between two materials, walking across the floor creates static buildup.

“A static charge can damage an electronic component like the ones they’re working on,” said Ron Puszynski, president of coatings contractor Concare Inc. “You can be at 10 V and damage some-thing, whereas you [as a person] can’t really feel a static electrical charge unless it gets up to about 1,500 V. You could be walking around all day long and zapping components without even knowing it.”

Fortunately for X-ES, Concare has installed electrostatic dissipative (ESD) floors since the mid-1980s. So when the client reached out to ESD flooring systems company ava for a solution, the manufacturer already had a trusted contractor ready to apply its system. 

“It’s not the only thing that we do, but it’s one of those specialty niches that we’re very good at and have gotten a reputation for over a long period of time,” Puszynski said.

Tilt Up Construction Challenges

One early challenge was handling the new concrete. For the 34,000-square-foot (3,158.7 m2) production area, X-ES opted for the on-site manufacturing of tilt-up wall panels. In this process, the concrete floor slab is poured first, followed by the tilt-up contractor framing out wall panels on the floor. From there, they spray a release agent and pour the concrete into forms. Anchors and lifting hooks are inserted into panels, which are then “tilted” into place. Moisture levels were first measured by the ESD contractor using a Rapid RH [relative humidity] concrete moisture test and shared with the material supplier to ensure the system had sufficient moisture tolerance. That tool came from Wagner Meters.

The choice for X-ES’s
production floor was the HB-97.2 epoxy line from StaticWorx.
Unfortunately, the aforementioned release agent that keeps the concrete from adhering to the floor can also prevent ESD coatings from sticking to it. Thus, once the new floor was ready to be coated, extensive surface preparation for the nine-man Concare crew was a must. Blasting was the method of choice, because the heat of a grinding operation could emulsify the release agents and drive them further into the slab.

Ongoing installation of Generation 3 Epoxy flooring at an electronics manufacturing and testing facility Wearing personal protective equipment (PPE) such as safety glasses, hard hats, steel-toed boots, and long pants and long-sleeved shirts in case of spills, the crew used a Blastrac 2-30D shot blasting unit for an abrasive blast cleaning. “This exposed the surface area, which aided in the release of any moisture that might be trapped underneath the surface,” Puszynski explained. To create a uniform surface, the crew took extra care when blasting.

“You can adjust the speed and size of media with these abrasive blast cleaning machines,” Puszynski said. “We used a very fine media and a very fast speed, and we went over the floor I think three times and crossed directions so that we never had any overlap lines that showed through.”

Another preliminary challenge related to the tilt-up design involved spot repairs and the filling of joints. “If you’re installing an ESD coating, you need to understand that you’re creating a conductive uniform surface,” Puszynski explained. “Every place that there was a control joint or a construction joint or any other type of break in the floor, we had to bridge all of those and fill in those joints and any cracks.” Crew members used a diamond-blade saw to clean out joints, then placed a backer rod into each joint so the sealant had a place to stop. Then, a two-component JF Polyurea filler was injected into each joint.

Ongoing installation of Generation 3 Epoxy flooring at an electronics manufacturing and testing facility Wearing personal protective equipment (PPE) such as safety glasses, hard hats, steel-toed boots, and long pants and long-sleeved shirts in case of spills, the crew used a Blastrac 2-30D shot blasting unit for an abrasive blast cleaning. “This exposed the surface area, which aided in the release of any moisture that might be trapped underneath the surface,” Puszynski explained. To create a uniform surface, the crew took extra care when blasting.

“You can adjust the speed and size of media with these abrasive blast cleaning machines,” Puszynski said. “We used a very fine media and a very fast speed, and we went over the floor I think three times and crossed directions so that we never had any overlap lines that showed through.”

Another preliminary challenge related to the tilt-up design involved spot repairs and the filling of joints. “If you’re installing an ESD coating, you need to understand that you’re creating a conductive uniform surface,” Puszynski explained. “Every place that there was a control joint or a construction joint or any other type of break in the floor, we had to bridge all of those and fill in those joints and any cracks.” Crew members used a diamond-blade saw to clean out joints, then placed a backer rod into each joint so the sealant had a place to stop. Then, a two-component JF Polyurea filler was injected into each joint.

Conductive Coating

The crew waited for the last possible opportunity to install the ESD coating system to allow for maximum dryness of the new, bare concrete. The choice for X-ES’s production floor was the HB-97.2 epoxy line from StaticWorx, which includes both an epoxy primer and polyurethane topcoat. Using 18-inch (45.7 cm) rollers, the moisture-tolerant primer was applied over consecutive days in two coats at ~12 mils (304.8 microns) of wet film thickness (WFT) each time. No additional PPE, such as respirators, was needed for the crew, since the coatings are extremely low in volatile organic compounds (VOCs).

 “We put in two coats of the primer material,” Puszynski said. “The fist coat, we add a bit of thinner to it to increase the viscosity so that it penetrates better. You want to get that stuff into the concrete as far as you can. Then the second layer creates a uniform plane all the way across the floor. That gives you a nice, uniform surface to apply the static-controlled topcoat.”

Prior to topcoating, Concare installed ESD grounding straps in locations designated by X-ES and their electrical contractor. Then, the StaticWorx 97.2 ESD Topcoat was applied as the system’s finishing layer at an average of 6 mils (152.4 microns) WFT. In that final coating, Concare added very fine, clear glass beads to provide added safety texture for the floor.

Rave Reviews

Within 10 days, the crew successfully installed the entire ESD flooring system, which allowed X-ES to remain on schedule to open its new production area. “The results were even better than expected,” Puszynski said. “When the project is completed, a week or two later, the manufacturer comes in and tests the floor for compliance with ESD products. They test the entire floor. They came in and did their testing, and they said they had not seen a floor produce as uniform a consistent a static discharge finish as this one. The ESD properties are somewhat dependent on the thickness of the  coating application, and this was applied so uniformly that they said there was virtually zero variation.”

While the floor ultimately looked attractive as well, the contractor says its success came from intense focus on performance. “This is like a piece of production equipment,” Puszynski said of the floor. “The customer wouldn’t do it just to make it pretty. They do it for a specific, highly critical part of their application. They’re looking for performance properties, as opposed to decorative or a glossy finish. That’s really the key. That’s why they’re buying it.”

The results were even better than expected.

The extra charge from Concare’s crew ensured the floor wouldn’t have one!

GroundWorx Ultra Epoxy

OFF-WHITE
Light Gray
Medium Gray
Dark Gray
Umber
Light Blue
Beige
OFF-WHITE
Light Gray
Medium Gray
Dark Gray
Umber
Light Blue
Beige
HB97.2
Moisture Tolerant Primer-A

HB97.2
Moisture Tolerant Primer-B

HB97.2
Primer Colorant

HB97.2
ANSI/ESD 20.20-2014 Compliant Top Coat A
HB97.2
ANSI/ESD 20.20-2014 Compliant Top Coat B

HB97.2
Top Coat Colorant

HB97.2
Slip Resistant Aggregate Additive
Learn about GroundWorx Ultra.
Download the GroundWorx Ultra brochure.

With StaticWorx ESD flooring, you never have to choose between performance and aesthetics. Our beautiful, high quality ESD carpet tile, vinyl, EC rubber tile and sheet goods, and ESD epoxy floors are as beautiful as they are functional.

Call Us: 617-923-2000
Tell Us About Your Project

Filed Under: Case Studies, ESD Products

Footer

Vermont Collection/ESD Planx

Staticworx Vermont Collection

Staticworx Vermont Collection

Visit our main site to learn more

Share This

Get in touch

Call: 617-923-2000
Email: info@staticworx.com
Contact Us

Connect with Us

  • Twitter
  • LinkedIn
  • Instagram
  • Pinterest
  • YouTube
  • SoundCloud

Subscribe for news/updates

Sign up for our newsletter and occasional updates.
Subscribe to Our Newsletter

Why Choose Staticworx?

Find out why our clients trust us.
Learn more

Do you have an ESD flooring project you’d like to discuss?
Share Your Project

Flooring Products

•Rubber •Carpet •Vinyl Tile •Epoxy Coatings •Snap-together, adhesive-free tiles •Conductive Adhesives • Adhesive-free underlayments •Static-control maintenance supplies •Test equipment

Request a sample

The FAA has updated its standard for facilities and electronic equipment. StaticWorx meets all requirements for ESD flooring.

This site is protected by copyright and trademark laws under both United States and International law.
All rights reserved. © 2008 - 2021, StaticWorx® Grounded Solutions™ · Privacy Policy

This website uses cookies to improve your experience. We'll assume you're ok with this, but you can opt-out if you wish. Privacy policy Cookie settings ACCEPT REJECT
Privacy & Cookies Policy

Privacy Overview

This website uses cookies to improve your experience while you navigate through the website. Out of these cookies, the cookies that are categorized as necessary are stored on your browser as they are essential for the working of basic functionalities of the website. We also use third-party cookies that help us analyze and understand how you use this website. These cookies will be stored in your browser only with your consent. You also have the option to opt-out of these cookies. But opting out of some of these cookies may have an effect on your browsing experience.